6
Selection Criteria
To correctly select the dryer best suited for your
application, the following details are required
to ensure optimum performance and trouble
free operation.
■ Maximum Inlet Flow
■ Minimum Inlet Pressure
■ Maximum Inlet Temperature.
Once these operating parameters have been
established, you can select the most economical
PNEUDRI MiDAS for your application.
Flow Rates
Model
m
3
/hr cfm
DAS1 5.1 3
DAS2 8.5 5
DAS3 13.6 8
DAS4 17.0 10
DAS5 22.1 13
DAS6 25.5 15
DAS7 34.0 20
Example
Selecting a dryer for a compressor producing, at full load 13.6m
3
/hr
(8cfm) at 6 bar g (87psi g) with 35°C (95°F) air inlet temperature and
a pressure dewpoint requirement of -40°C (-40°F).
Step 1
From the sizing chart select the required pressure @ 6 bar g (87psi g)
and read across to the required inlet temperature @ 35°C (95°F). The
Correction Factor is 0.88
Step 2
To adjust the flow for your application, divide the required flow by the
0.88. Correction Factor
Example:
Sizing Capacity = Actual Flow 13.6m
3
/hr (8cfm) = 15.5m
3
/hr (9cfm)
Correction Factor 0.88
Step 3
From the Model Selector, select the dryer which has a rated flow
capacity of 15.5m
3
/hr (9cfm) or higher.
Selected model for this example is a PNEUDRI MiDAS DAS 4.
Sizing Chart (Correction Factors)
Model Selector
Referenced to 20°C (68°F) and 1bar a (14.5 psi a)
Minimum Inlet Pressure Maximum Inlet Temperature °C (°F)
bar g psi g 35 (95) 40 (104) 45 (113) 50 (122)
4 58 0.63 0.61 0.55 0.46
5 73 0.75 0.73 0.66 0.55
6 87 0.88 0.85 0.77 0.64
7 100 1.00 0.97 0.88 0.73
8 116 0.97 0.94 0.85 0.71
9 135 1.08 1.05 0.95 0.79
10 145 1.18 1.14 1.04 0.86
11 160 1.29 1.25 1.14 0.94
12 175 1.40 1.36 1.23 1.02